Turbidity is a measure of how cloudy water is due to suspended particles. It’s usually reported in nephelometric turbidity units (NTU).
On construction and civil sites, fine silt, clay and other material carried in the water can increase turbidity. Monitoring it helps show when water conditions or treatment performance start to change.
Fine sediment in runoff, groundwater and excavation water can increase turbidity. Very fine particles can stay suspended after heavier material has settled – so gravity settling alone may not always reduce turbidity enough.
A turbidity sensor sends light through the water and measures how suspended particles scatter that light. The amount of light scattered gives the NTU reading.
Comparing cloudy site-water samples can show visible differences in turbidity
No – turbidity and TSS are related, but they measure different aspects of water quality:
Turbidity measures how suspended material affects light passing through the water
TSS measures the concentration of suspended solids in the water.
Particle size, shape and other characteristics can affect how much light the water scatters – so an NTU reading doesn’t directly translate to a TSS concentration.
If a project specifies both turbidity and TSS, check each against the monitoring requirements for that job.
Turbidity monitoring can help show whether incoming water quality or treatment performance is changing.
For example, Prime recommends checking water leaving a lamella clarifier against the site requirements – including turbidity where specified. Monitoring systems can also track readings over time and send alerts when a set limit is reached.
A change in turbidity can point to a change in the water or treatment process – but the reading alone won’t tell you the cause.
Check the incoming water, treatment setup and other relevant measurements before deciding what needs adjusting.
Turbid site water moving through a Prime lamella clarifier.
No – a low turbidity reading alone doesn’t mean the water meets all discharge requirements. Depending on the site and discharge requirements, you may also need to check:
pH
Prime looks at the water and project requirements together rather than relying on one measurement.
Prime’s water quality monitoring systems can track turbidity alongside measurements such as flow and pH.
The setup depends on what the project needs to monitor and where readings have to be taken. If turbidity reaches a set limit, the system can alert your site team.
Need to monitor water quality on site? Explore Prime’s water quality monitoring systems for tracking turbidity, pH and flow as part of a site water treatment setup.
Coagulation | Flocculation | Groundwater | Lamella Clarifier | Incline Plate Settling | Sludge Hopper | Total Suspended Solids